top of page

PXC5PHTSS-TS04 POWERBAR ขนาด 4 ช่อง

ddddddddd.png

INTELLIGENT PDUs

 PX Intelligent PDUs offers more than just power distribution.

PX Intelligent PDUs, under FibreConneX Limited., independent research and development can effectively and accurately monitor the changes of current, voltage and power consumption of equipment in server rooms in real-time. Server room administrator can export energy consumption of server room equipment in a certain time quickly and easily and analyze it effectively, then make the immediate decision to reduce the consumption. Energy saving of datacenter is both responsibility and duty. PowerConneX remote monitoring and management PX Intelligent PDUs is indispensable expert of energy saving in datacenter.

PX Intelligent PDUs is offered in four different feature levels:

1.png

Designed
for high availability

2.png

Optimized energy and capacity management

3.png

Simplified integration with management tools

4.png

Compatibility with racks and power chain

etesbdz.png

Main Functions

  • PX Intelligent PDUs, under FibreConneX Limited., independent research and development can effectively and accurately monitor the changes of current, voltage and power consumption of equipment in server rooms in real-time. Server room administrator can export energy consumption of server room equipment in a certain time quickly and easily and analyze it effectively, then make the immediate decision to reduce the consumption. Energy saving of datacenter is both responsibility and duty. PowerConneX remote monitoring and management PX Intelligent PDUs is indispensable expert of energy saving in datacenter.

  • PX Intelligent PDUs is offered in four different feature levels:

Monitored per PDUs (MP)
  • PDUs that have the ability for aggregate power monitoring to quickly identify potential power issues, and reclaim available or underutilized power capacity.

Monitored per Outlets (MO)
  • PDUs that have the ability for outlet level power monitoring to quickly identify potential power issues, and reclaim available or underutilized power capacity at the outlet level enabling the redeployment or decommissioning of individual servers to reclaim available or underutilized power capacity.

Monitored per PDUs and Switched (MPS)
  • PDUs that have the ability for aggregate power monitoring and outlet level switching capabilities for individual outlets or a group of outlets. Enabling power sequencing, rebooting equipment or restrict unauthorized use of individual outlets.

Monitored per Outlets and Switched (MOS)
  • PDUs that have the ability for outlet level power monitoring and outlet level switching capabilities for individual outlets or a group of outlets. Power monitoring at the individual outlet level provides actionable management data on the power consumption of each

  • connected IT device enabling the redeployment or decommissioning of individual servers to reclaim available or under-utilized power capacity.

k77sf.png
  • Centralized management software - PowerConneX Manager is designated power and environmental monitoring solution for data center managers.

  • It can monitor and manage all the power data, operation status and IT environments from PX Intelligent PDUs. The software has the characteristics of concurrent data collection, multi-thread polling, daisy-chain connection, free-of-installation and etc. The features of automatic equipment identification, bulk firmware upgrade, one-button set up and fast response time make it suitable for small and medium-sizes data center which hosting less than 1000 PDUs and enables facility managers to closely monitor and efficiently utilize their existing data center.

  • This software is safe, efficient, reliable and scalable, which enables you to reduce capital and operating expenditures by providing the information and control you need. And it also helps to improve energy efficiency management of your existing power infrastructure.

  • DCIM as tools used to “monitor, measure, manage and/or control data center utilization and energy consumption of all IT-related equipment.”

  • While data center management is the set of strategies and techniques

DCIM Integration
  • administrators develop and use to operate their IT facilities, DCIM most often refers to the software tools and solutions that managers can rely on to help visualize and manage their critical assets. Data center infrastructure itself is the core physical or hardware-based resources and components – including all IT infrastructure devices, equipment, and technologies – that comprise a data center.

Environmental Sensor
  • Compatible with a vast and expanding

  • ecosystem of plug-and-play environmental sensors, PX Intelligent PDUs allow temperature, humidity, door lock

  • security, smoke detection, water leakage detection to be both simple and economical.

  • Smoke sensor

  • Sensor status Light

  • Temperature/Humidity sensor

  • Door sensor

  • Water Leakage sensor

หผห.png

Key Features of Intelligent PDUs

9.png

Real-time Monitoring

of Power Environmental and Physical Access Security

13.png

Cable Retention Clip

effectively prevent downtime caused by accidental cable fall out.

10.png

Environmental Sensors

easily monitor the cabinet environment with a verity of external sensors.

14.png

Daisy-Chain

enables multiple PX PDUs to share the same network thus to save IP resources.

11.png

Low Profile Hydraulic Circuit breakers prevent current overload in each branch circuit and keep PDU running stable.

15.png

Build-in Web Interface

monitors PDUs parameters via web browser with no dedicated software required.

12.png

kWH Metering Accuracy

accurate kWh metering allows you to measure actual energy usage for accurate customer or department charge-back billing.

16.png

DCIM Integration

integrate to communicate with existing DCIM or BMS solution through SNMP or standard Modbus interface.